نحن نستخدم ملفات تعريف الارتباط لتحسين تجربتك على الإنترنت. من خلال الاستمرار في تصفح هذا الموقع ، نفترض أنك توافق على استخدامنا لملفات تعريف الارتباط.

Professional Medical Equipment Supplier - Yuesen Med Professional Medical Equipment Supplier - Yuesen Med

فئات

جهاز التنفس الصناعي الطبي في المستشفى YSAV50A

رقم البند.: YSAV50A
جهاز التنفس الصناعي الطبي في المستشفى YSAV50A
احصل على السعر
وصف

Medical ventilator hospital respirator YSAV50A 
 
TECHNIQUES SPECIFICATIONS
Physical specifications 
Display LED Display
Mode: pneumatically powered and electrically controlled system
Trolley:  Fitted with 4 nos anti-static rubber castors; two of which are lockable for 
braking and easy maneuverability with foot operated brake provisions
Technical Specifications:
Gas requirement:  Medical oxygen with a pressure ranging from 280~600kpa
safety valve  <12.5  kPa
Respiratory Rate 6~60 times/ min
Oxygen concentration output <50%
minute volume ≥18L 
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH
PEEP: 0.1 ~ 1.0 kPa
Ptr:  -4 ~ 10 hPa
IMV frequency: 1~12 bpm
I/E Ratio: 1:1.5; 1:2.0; 1:2.5; 1:3.0
Tidal Volume Not less than 50~ 1200ml
Inspiratory Plateau: 0~1s
Maximum Safety  Pressure ≤ 6.0kPa
Sigh:  one deep breath per 80 controlled respirations, the inspiration 
time is 1.5 times of the setting point
Pressure limit range: 0 ~ 6.0 kPa
Airway pressure alarm: Audible and visual 
and with yellow and red color indicating
Lower: 0.9 kPa ~ 5.4 kPa;   Upper: 0.5  kPa
±0.2 kPa
Ventilation Volume alarm:  ≥ 18L/ MIN 
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, 
the pressure will be displayed in red and the continuous 
high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature:  10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa 1060 hPa
Power requirement:  100-120 Vac, 50/60 Hz;  
Attention: the AC power supply used for the ICU ventilator must be well   grounded.
Storage
Ambient temperature:  -15oC ~ +50oC
Relative humidity:  no higher than 95 %
Atmospheric pressure:  86 kPa ~ 106 kPa.
  It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
  Between the packaging box and product, soft material with appropriate 
thickness provided to prevent loosening and mutual friction during transportation
  Moisture protection and rain protection to ensure that product is 
protected from natural damage. 
Safty & Alarm
Gas source pressure Immediate alarm; “high level alarm” indicator flickers raising an audible alarm.
Airway Pressure Alarm The airway pressure exceeds 15hpa. The maximum delay is no longer than 
17s. The “high level alarm” indicator flickers raising an audible alarm. 
Tidal Volume Alarm Lower than 50ml, The alarm will be raised after one breathing cycle. 
Ventilation Volume Alarm Lower: 0~12L/Min;   Up: 18L/ Min
Battery Voltage Alarm It alrms when the battery voltage is lower than 10.5V.
Power On Self Test Self test before working, assure it's working normally. 
STANDARD CONFIGURATIONS  
QTY NAME
1 set Main unit
1 set Oxygen tube
2 set Silicone Mask
1 pc Power line
2 pcs Threaded pipe
2 pcs Standard Pipe
1 set Oxygen Reducer
1 set Humidifier
1 pc Battery
1 set flow sensor
2 pcs A leather bag ( Blue)
1 set Tools with the machine
1 set User Manual (English Version)
احصل على السعر
اكتب طلبك أدناه وسنتصل بك في غضون 24 ساعة!

YOUR MAY ALSO LIKE ...
جهاز التنفس الصناعي LCD المحمول 10.4 بوصة YSAV203
جهاز التنفس الصناعي LCD المحمول 10.4 بوصة YSAV203
5.7 بوصة شاشة LCD عرض التنفس الصناعي النقل الطبي YSAV201M
5.7 بوصة شاشة LCD عرض التنفس الصناعي النقل الطبي YSAV201M
YSAV-H602 التنفس الصناعي الطبي المحمول COVID-19
YSAV-H602 التنفس الصناعي الطبي المحمول COVID-19
وحدة العناية المركزة الطبية YSAV400B
وحدة العناية المركزة الطبية YSAV400B