Categorías
Máquina DE RAYOS X de diagnóstico de alta frecuencia móvil 5kW YSX100GM
Artículo No.: YSX100GM
Máquina DE RAYOS X de diagnóstico de alta frecuencia móvil 5kW YSX100GM
Parametros del producto | |
Marca: | YSENMED |
MOQ: | 1 |
Paquete: | Paquete de cartón |
Nave de: | Guangzhou |
Tiempo de espera: | 1-3 días |
Personalización: | Yes |
Descripción
5kW Mobile High Frequency Diagnostic X-Ray Machine YSX100GM
Combined X-Ray Tube Assembly
1,Adopt high frequency high voltage generator and combined X-ray tube assembly;
2,kV closed-loop control, stable output, good repeatability, quick response and high accuracy;
3,mAs digital closed-loop control technology and 32-bit microprocessor real-time control, which ensure the accuracy and repeatability of dosage;
Inverter
1,Equipped with the functions of high voltage and over & under voltage protection, tube current over-current protection, output overload protection and fault prompt;
2,Perfect heat capacity protection function to protect X-ray tube target surface;
Corrugated Pipe
Full consideration of hospital disinfection and cleaning, adopt high quality corrugated pipe, prolonging the service life of the equipment
Switch
Using high quality switch, safe and reliable, stable quality
Technique Specification
Model | YSX70GM-B | YSX100GM | |
Power | |||
Input Voltage | 220V±10% | ||
Input Power | 5.5kW | 7.5kW | |
Mains Frequency | 50Hz±1Hz | ||
Source Resistance | ≤0.5Ω | ||
Main Technical Parameters | |||
Power Modules | 30kHz | ||
Filament Frequency | 20kHz | ||
Focus | 1.5mm | ||
Max. Generator Output | 3.5kW; | 5kW | |
Max. X-Ray Tube Voltage | 110KV | 120KV | |
kV Range | 40~120kV | ||
mAs Range | 1~125mAs | 1~200mAs | |
Main Parameters Of Mechanical Parts | |||
X Ray Tube Vertical Motion Range | ≥500~1750mm | ||
X Ray Source Components Around The Cross Arm Vertical Rotation:≥±90° | |||
Exposure Size | ≥350mm*350mm(SID=65cm) | ||
Machine Main Function | |||
Fault Detection Error Prompt Functions | |||
ARP Human Anatomy Program Function | |||
Parameter Calibration Function |
Combined X-Ray Tube Assembly
1,Adopt high frequency high voltage generator and combined X-ray tube assembly;
2,kV closed-loop control, stable output, good repeatability, quick response and high accuracy;
3,mAs digital closed-loop control technology and 32-bit microprocessor real-time control, which ensure the accuracy and repeatability of dosage;
Inverter
1,Equipped with the functions of high voltage and over & under voltage protection, tube current over-current protection, output overload protection and fault prompt;
2,Perfect heat capacity protection function to protect X-ray tube target surface;
Corrugated Pipe
Full consideration of hospital disinfection and cleaning, adopt high quality corrugated pipe, prolonging the service life of the equipment
Switch
Using high quality switch, safe and reliable, stable quality