Descripción
Medical hospital equipment Multi-parameter patient monitor YSF3
The YSF3 vital signs monitor is engineered for the mobile, precise and fast recording of vital signs
data at clinics, hospitals and outpatient treatments. Ergonomical design and highly developed technology
resulting in reliable measurement results and time efficiency.
data at clinics, hospitals and outpatient treatments. Ergonomical design and highly developed technology
resulting in reliable measurement results and time efficiency.
12V DC power supply for ambulance use
An optional HDMI output eases observation from a long distance.
Core
Newly advanced A8 main board with Linux OS, calculating speed is 4 times faster than traditional products
Support storage of 2160 hours trend table and graph review, 2 hours waveform review, 2000 groups
NIBP review and 2000 alarm events review
NIBP review and 2000 alarm events review
Body
7 inch high-brightness TFT LED
Standard touch screen configuration
Optional HDMI output
Printer
USB External high-speed 50mm thermal printer
(Brand: SEIKO, Japan)
Central System
Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.
Optional Support HL7 (Health Level Seven)
Alarm
Three-level acousto-optic alarm
Sensor-off alarm
Paper out alarm
Support alarm review
Support alarm pause
Linux OS
Multi-display mode to meet different clinical requirement
NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
Generate ID automatically when register a new patient
Support medical history search by patient ID, name and mobile number
Optional infrared thermometry allows clinicians to obtain patient’s temperature using non-invasive infrared technology that detects heat from the skin’s surface
18 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
Drug calculation and titration table
Support multi-language display
Support online software upgrading by net/USB
Suitable for monitoring adult, pediatric and neonatal patient.
Interface
Transducer socket
ECG
SPO2
NIBP
TEMP 1
Mainstream EtCO2
LAN / Central monitor system interface
The LAN port is for connecting the monitor to a central monitor system network.
Input device interface
This optional interface provides an USB ports to enable the monitor to be connected to off-the-shelf input devices:
Mouse: any specified trackball or USB mouse may be used for navigation and data entry.
Computer keyboard: an USB computer keyboard can be used for data entry instead of the on-screen pop-up keyboard.
[Remark: user has to restart the machine after plug and unplug the mouse / computer keyboard.]
Touch screen (Standard)
[Remark: Touch screen can not be used simultaneously with mouse / computer keyboard.]
Service Features
The Support Tool helps technical personnel to
– carry out configuration, upgrades and troubleshooting on an individual monitor.
–back up the monitor settings.
The Service Mode is password-protected and ensures that only trained staff can access service tests and tasks. It includes Skin Type, Brightness Setting, Clear Data, NIBP Calibration and Touch Screen Calibration.
The Support Tool uses the USB interface of the monitor for software upgrading.
Related Product
Infrared thermometry
Suntech NIBP module
Respironics EtCO2 module
Nellcor SpO2 module
Masimo Spo2 module
Performance Specifications
Dimension and Weight
-Dimension: 210mm*130mm*75mm
-Weight: 1kg(excluding accessories)
Power Supply
-Voltage: AC100~240V, 50/60HZ
-Adapter: Output 9VDC, 5A
Display
-7" color TFT LED
-Resolution: 800*480 pixels
Battery
-Type: Rechargeable lithium battery 7.4V/2200mAh
-Charge Cycle: ≥500 times
-Working time: 2-3 hours (optional larger battery for 4-5 hours)
Recorder (Option)
-Method: USB External Thermal printer
-Paper width: 50 mm (1.97 in)
-Printing speed: 12.5/ 25/ 50 mm/s
-Trace: Max. 3 tracks
-Recording way: Real-time Recording, Review Printing,
Periodic Recording, Alarm Recording
Alarm
-Level: Low, medium and high
-Indication: Auditory and visual
-Alarm volume adjustable
-Alarm pause time: 1min, 2min
-Parameter alarm type: Latch/ Unlatch
Input Device
-Touch screen (standard)
-Touch pen (standard)
System Output & Extensible Interface
-Ethernet Network: 1 standard RJ45 socket
-USB Port: 1
-Video Output: 1 HDMI port (option)
Operating Environment
-Temperature: 5 ~ 40 ℃
-Humidity: 15% ~ 80% (non-condensing)
-Atmosphere pressure: 86 KPa ~ 110 KPa
Transportation and Storage Environment
-Temperature: -20~50 ℃
-Humidity: 10%~90% (non-condensing)
-Atmosphere pressure: 86 KPa ~ 110 KPa
Safety
-IEC60601-1 Approved, CE marking according to MDD93/42/EEC
-With reference to RoHS Directive 2011/65/EU recasting
Trend & Reviewing
-Trend: 2160 hours
-ARR events: 128 groups of ARR events and associated waveform
-NIBP measurement reviewing: 2000 groups
-Waveform review: 2 hours
-Alarm event: 2000 groups of parameter alarms events and associated parameter
ECG
-Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
-Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof
-Gain: 2.5mm/mV (×0.25), 5.0mm/mV (×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
-Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
-ECG signal range: ±12 mV (Gain × 0.25)
-Accuracy: ±1bpm/ ±1%, whichever is greater
-Resolution: 1 bpm
-Leakage Current < 10 μA
-Baseline Recovery:
≤ 3s after defibrillation (Monitor mode)
≤ 1s after defibrillation (Surgery mode)
-Bandwidth: Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 120 Hz
-Indication of Electrode Separation: Every electrode (exclusive of RL)
Heart Rate
-Measure range:
Adult: 0bpm; 10 ~ 300 bpm
Neo/Ped: 0bpm; 10 ~ 350 bpm
-Resolution: 1 bpm
-Accuracy: ± 1% or ± 1bpm, whichever is greater
ST Measurement
-Range: -2.0 ~ +2.0 mV
-Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
-Other range: unspecified
-Resolution: 0.01mV
Respiration
-Method: Impedance between RA-LL, RA-LA
-Gain: ×0.25, ×0.50, ×1, ×2, ×4
-Respiration Rate: 0bpm, 6 ~ 150 BrPM
-Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s
-Resolution: 1 BrPM
-Accuracy: ±2 bpm or ±2%, whichever is greater
-Apnea Alarm: 10 ~ 60 s
Temperature
-Technique: Thermistor probe (2.25K)
-Channel: Single-channel
-Measuring and Alarm
Range: 0.0 ℃~ 50 ℃ (32℉~ 122℉)
-Unit: Celsius (℃), Fahrenheit ( ℉)
-Resolution: 0.1℃or 1℉
-Accuracy: ±0.1℃(exclusive probe)
NIBP
-Method: Oscillometric
-Measure mode: Manual, Auto, STAT
-Measure Interval in AUTO Mode 1~480 min
-STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
-Measure and Alarm Range:
Adult: SYS: 30 ~ 270 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric: SYS: 40 ~ 235 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 225 mmHg
Neonate: SYS: 30 ~ 135 mmHg
DIA: 10 ~ 110 mmHg
MEAN: 20 ~ 125 mmHg
-Static pressure accuracy: ±3mmHg
-Resolution: 1mmHg
-Accuracy: Maximum Mean error ±5mmHg
Maximum Standard deviation ≤8mmHg
-Over pressure Protection: Dual protection via software & hardware
Performance Specifications
Suntech NIBP
-Measure Method: Oscillometric. Diastolic values correspond to Phase 5 Korotkoff sound
-Measure Range:
Adult: SYS: 40 ~ 260 mmHg
DIA: 20 ~ 220 mmHg
MEAN: 26 ~ 220 mmHg
Pediatric: SYS: 40 ~ 230 mmHg
DIA: 20~ 160 mmHg
MEAN: 26 ~ 183 mmHg
Neonate: SYS: 40 ~ 130 mmHg
DIA: 20 ~ 100 mmHg
MEAN: 26 ~ 110 mmHg
-PR Range: 30 to 220 BPM
-PR Accuracy: ±2% or ±3 BPM, whichever is greater
-Pressure Transducer Accuracy: ±3mmHg between 0 mmHg and 300 mmHg
for operating conditions between 0℃ and 50℃
-Deflate Rate: Deflation step size varies with heart rate, cuff pressure and cuff volume
-Initial Inflation Pressure:
ADULT: 160 mmHg (default)
Variable from 120 to 280 mmHg
PEDIATRIC: 140 mmHg (default)
Variable from 80 to 280 mmHg
NEONATE: 90 mmHg (default)
Variable from 60 to 140 mmHg
SpO2 (Digital Technic)
-Measurement Range: 0 ~ 100 %
-Resolution: 1 %
-Accuracy: ±2% (70% ~ 100%)
±3 % (35% ~ 69%)
Unspecified (0 ~ 34%)
-Support Pitch tone and multi-level volume
Pulse Rate
-Measuring and Alarm Range: 25~250bpm
-Accuracy: ±1% or ±1 bpm, whichever is greater
-Resolution: 1bpm
Nellcor-SpO2 (Option)
-Measurement Range: 0 ~ 100 %
-Resolution: 1 %
-Accuracy: 70% ~ 100%, ±2 %