Nous utilisons des cookies pour améliorer votre expérience en ligne. En poursuivant votre navigation sur ce site, nous supposons que vous acceptez notre utilisation des cookies.

Professional Medical Equipment Supplier - Yuesen Med Professional Medical Equipment Supplier - Yuesen Med

catégories

Système d'arceau Digital Pixels

No. d'article: YSX-C50D
Dernier système d'arceau numérique Pixels à vendre à bon prix.
Paramètres du produit
Marque: YSENMED
MOQ: 1
Paquet: Paquet en bois
Expédier de: Guangzhou
Délai: 1 à 3 jours
Personnalisé: Yes
Obtenir le prix
Description

Digital Pixels C-arm System


Technical Specifications & Configuration

Main components Technique parameter
IMD X-ray tube YSX-C35D YSX-C50D
Power:3.5kW Power:5.0kW
Double focus fixed anode focus:1.5mm / 0.6mm Double focus rotational anode focus: 0.3mm / 0.6mm
Anode Heat Capacity:40kHu X-ray tube sleeve heat capacity:667kHu Anode Heat Capacity:200kHu X-ray tube sleeve heat capacity:800kHu
High Voltage X-ray Generator Working frequency:40kHz
Image intensifier Toshiba 9"(including 3 fields of view 4.5"/ 6"/9")
Tube voltage Fluoroscopy Radiograph:40kV-110kV Fluoroscopy Radiograph:40kV-120kV
Tube current Fluoroscopy: 0.5-4mA  Enhanced  Automatic Fluoroscopy: 1mA-8mA    Pulse  Fluoroscopy :2pps;8mA
mAs 1mA.s-250mA.S
Fluoroscopy  mode Manual  Fluoroscopy; Semi-Automatic Fluoroscopy;Automatic Fluoroscopy; Enhanced  Automatic Fluoroscopy; Pulse  Fluoroscopy
Intelligent exposure control No matter the object is in the center or on the fringing field of the image intensifier, the images are the same. The exposure dose is reduced.
Iris beam limiting device when not exposure, keep in the state of Iris Beam limiting preview ,when exposure,keep blanking cycle track
General radiography 40kV-120kV;1.0mA.s-250mA.s step length 1 kV;1.0mA.s
Digital radiography (digital spot film) 40kV-120kV;Max 16mA Common screen film radiography is eliminated. Digital radiography can get better images
C-arm machinery index C-arm stander(with perfect C arm balance system) of ultra-quiet motor-driven up and down, easy and handy to operate. The machine can maintain balance with up and down of the C arm.
Distance between focus and window900mm, arc depth650mm, horizontal moving range :200mm vertical moving range:400mm
Tilt angle :±12.5°  rotation :±180°corner:125°(-35°-- +90°)
Laser Orientation Laser positioning function can help to position precisely and reduce exposure times in the operation, reduce unnecessary radiation.
Radiography mode
Image intensifier & Real-time digital image(1.3 million pixel) processing system
(CCD)Digital video  camera million pixels high-definition, high-speed CCD camera, a 1024 × 1024 matrix, 30 frames per second image acquisition, through real-time adjustment of window width, window level, noise reduction, sharpening and Gain adjustment to ensure high-quality and high-resolution images.
Image  resolution  index Grey level:10  Resolution:22 lp/cm
Camera virtual  rotation design No X-ray needed, also called digital image rotation,display the right angle when exposure, superior to camera  mechanical  rotation
Image processing  system 1.Real time edge  enhancement(sharpening) Image sharpening is also called edge enhancement, that is, to make  blurry edge of the image clearer
2.Real time adjustment of the window width and window level Obtain images by real-time adjustment of window width,window level, displaying images with different brightness.
3.Real time(static)multiform noise reduction Noise reduction, and improve image clarity
4.Real tim GAIN adjustment Can amplify image signal, reduce x-ray dose, suitable for patient with super large size.
5.Real tim dynamic brightness compensation and R calibration functions Through dynamic logarithmic transformation,linear reduction the system signals and r calibration technology, dark parts of the image can be enhanced and clear rich-layer images can be obtained
6.Image conversing ,up-down and right-left rotating,and frame freezing
7.Patient information management ,Clinic report  and print
8.The Image can be storage as JPG and DICOM 3.0 format, can be linked to hard-disk ,USB  and DVD and printer,meet the need of sharing the network information ,communication  and  storage  in   hospital
Display Display2 17TFT-LCD display
Printer Printer Laser / jet Printer
Standard configuration 1.Combined tube(5.0kW)IMD 1 set;
2.Image intensifier (9 inch 3 fields of view) Toshiba 1 set
3.C-arm stander (with full C-arm balance system) 1 set;
4.Exported grid 1 set
5.Laser positioning 1 set;
6.1.3 million pixel 1024×1280×10bit camera 1 set;
7.Electric adjustable beam limiting device 1 set
8.17 inch LCD high resolution screen 2 sets
9.Real-time digital imageprocession system (station) 1 set;
10.Printer 1 set
Obtenir le prix
Notez votre demande ci-dessous et nous vous contacterons sous 24h!

YOUR MAY ALSO LIKE ...
Système de radiographie numérique avec bras en C numérique, détecteur à écran plat 15 kW, YSX-C715
Système de radiographie numérique avec bras en C numérique, détecteur à écran plat 15 kW, YSX-C715
Digital C-arm X-ray System with Flat Panel Detector YSX-C605
Digital C-arm X-ray System with Flat Panel Detector YSX-C605
Système de radiographie numérique à bras en C de 5,0 kW
Système de radiographie numérique à bras en C de 5,0 kW
Haute Fréquence mobile C-bras d'images de système YSX-C35B
Haute Fréquence mobile C-bras d'images de système YSX-C35B