catégories
20kW Numérique X Ray Machine Pour Les Grands Animaux YSDR-VET200
No. d'article: YSDR-VET200
Machine à rayons X numérique vétérinaire/radiographie numérique pour grand animal/ 20KW, scanner à rayons X
Description
20kW Digital X Ray Machine for Big Animals YSDR-VET200
Model Parameters |
YSDR-VET200 | YSDR-VET320 | |
Power | 20kW (can take clear images for the body no more than 35cm thickness ) | 32kW (can take clear images for the body no more than 50cm thickness ) | |
Power supply | Single-phase 220V 50/60HZ (wire diameter>4mm², internal resistance<0.5Ω) |
||
mA | 10~320 mA | 10~400 mA | |
mAS | 1~320Mas, stepping by R’10 | 1~400mAS, stepping by R’10 | |
KV | 40~125kV, stepping by 1kV | ||
Exposure time | 0.003~6.3S adjustment: Increased /reduced by 1mS each time |
||
X-ray tube | Toshiba 7239/7242, Toshiba 7239/7242, or Chinese brands are available for options | ||
Anode rotating speed/Anode heat capacity | 2800prm/140kHU |
||
Generator frequency | 400kHz | ||
Radiography table(W*L cm) | Width: 70cm, length: 140/120cm (either) urinary trough can be equipped with |
||
Flat panel detector | Imaging area | 17*17 inches (or 14*17 inches) | |
Pixel size | 140um | ||
A/D conversion | 16bits | ||
Spatial resolution | 3.6lp/mm | ||
Software | Professional veterinary software | ||
Computer configuration | Intel i5 processor; 8G memory, 2G discrete graphics card, 128G solid state drive + 1TB mechanical hard drive, PCI-E and Ethernet dual Gigabit network cable interface, R232 interface; 22.5-inch Dell professional small dot pitch monitor; operating system: win10 |
Customizable Options
1. The table length can be 1.2 m or 1.4 m;
2. The urinary trough of the table is optional according to needs
3. The 4 corners of the table is optional(angle R5-50)
4. The logo of the table can be customized with stainless steel stickers or screen printing; the stickers can be beautified and pasted by customers themselves.
5. Movable casters are optional;
6. X-ray tube is optional (imported or Chinese brands);
7. Flat panel detector is optional (multi-brands)
Installation Instructions
1.X-ray room: 20m2 room is recommended.
2. Lead glass size recommended: 40*60cm or 60*80 cm
3. X-ray protection preparation: use barium sulfate powder or lead sheet for the wall of the room, and lead sheet for the ceiling;
4. A fan must be installed on the top to facilitate the discharge of ionized air
5. All surfaces of the x-ray room that people can reach need to be covered with lead sheet or barium sulfate powder. If it is the first floor, the ground does not need to be covered; if it is the top floor and will not polluted the environment, lead protection is not required.
Service and Support
1. With 18 years of X-ray product R&D and production experience, we can provide more cost-effective and suitable products;
2. The components of X-ray machine including flat panle detector, can be installed and debugged according to the specifications required by the customer;
3. OEM customization is available for table LOGO and software interface;
4. The x-ray table can be designed and made according to the customer's drawings, and a confidentiality agreement can be signed for the clients.
YOUR MAY ALSO LIKE ...
YSX-VET320 Radiographie numérique haute fréquence pour animaux de compagnie
Machine à rayons X numérique 20kW pour grands animaux YSDR-VET320
Appareil de radiographie portable numérique vétérinaire YSX056-PE VET 5,6 kW