Categories
5.0kW 100mA Mobile Veterinary X-ray Machine YSX100VET
Item No.: YSX100VET
5.0kW 100mA Mobile Veterinary X-ray Machine YSX100VET
Product parameters | |
Brand: | YSENMED |
MOQ: | 1 |
Package: | Carton Package |
Ship From: | Guangzhou |
Lead Time: | 3-7 days |
Customization: | YES |
Description
5.0kW 100mA Mobile Veterinary X-ray Machine
YSX100VET
1. The power supply requirements
1.1 Voltage requirements: single phase line voltage to 220 + 10% for VAC, 50 Hz
1.2 Input electric power: 7.5 KVA standard ground wire or less
2. Generator
2.1 Inverting frequency: 60 KHZ or higher;
2.2 Filament frequency: ≥20 KHZ;
2.3 Focus: 1.5 mm
2.4 Max. output power: 5 kw
2.5 Radiography tube voltage range: 40 ~ 120 kv;
2.6 mAs range: 1 ~ 200 mas
2.7 Maximum tube current: 100 ma
3 Mechanical requirement
3.1 X ray tube focus range of vertical ground movement: 500 ~ 1750mm or higher;
3.2 X ray source component vertical rotation around the cross arm: + 90°or higher;
3.3 The limit of beam splitter spinning the ball tube window center around: p + 90°;
3.4 Radiography size: 350 mmx350mm or greater (at the SID = 65 cm);
Main functions
1.1 Voltage requirements: single phase line voltage to 220 + 10% for VAC, 50 Hz
1.2 Input electric power: 7.5 KVA standard ground wire or less
2. Generator
2.1 Inverting frequency: 60 KHZ or higher;
2.2 Filament frequency: ≥20 KHZ;
2.3 Focus: 1.5 mm
2.4 Max. output power: 5 kw
2.5 Radiography tube voltage range: 40 ~ 120 kv;
2.6 mAs range: 1 ~ 200 mas
2.7 Maximum tube current: 100 ma
3 Mechanical requirement
3.1 X ray tube focus range of vertical ground movement: 500 ~ 1750mm or higher;
3.2 X ray source component vertical rotation around the cross arm: + 90°or higher;
3.3 The limit of beam splitter spinning the ball tube window center around: p + 90°;
3.4 Radiography size: 350 mmx350mm or greater (at the SID = 65 cm);
Main functions
4.1 APR animal anatomy program function;
4.2 8 inches true color touch-screen operation interface;
4.3 Malfunctions auto-detecting;
4.4 Automatic calibration parameters;
5. Main configuration
5.1 One set of x ray source component
5.2 Collimator
5.3 Work station 1 set (computer control)
5.4 Mobile car 1 set
5.5 One set of remote control
4.2 8 inches true color touch-screen operation interface;
4.3 Malfunctions auto-detecting;
4.4 Automatic calibration parameters;
5. Main configuration
5.1 One set of x ray source component
5.2 Collimator
5.3 Work station 1 set (computer control)
5.4 Mobile car 1 set
5.5 One set of remote control
YOUR MAY ALSO LIKE ...