Categories
AEON 8300A Two Vaporizer Anesthesia Machine
Item No.: AEON 8300A
CE marked, meets EU clinical requirement
Enhances usability with auxiliary oxygen, suction, auxiliary power source, monitor arm, infusion pump etc.
Enhances usability with auxiliary oxygen, suction, auxiliary power source, monitor arm, infusion pump etc.
Product parameters | |
Brand: | YSENMED |
MOQ: | 1 |
Package: | Carton Package |
Ship From: | Guangzhou |
Lead Time: | 3-5 days |
Customization: | Customized packaging |
Description
AEON 8300A Two Vaporizer Anesthesia Machine
• PCV and SIMV+PS modes ensure flexibility in ventilation, machine doable for both pediatric and adult operation
• Optional monitoring functions, CO2 and anesthetic gas
• Flowmeter provides minimum 25% concentration of oxygen in O2 /N2O mixture
• Breathing system easy to remove and clean, fully autoclavable, optional CO2 bypass
• Enhances usability with auxiliary oxygen, suction, auxiliary power source, monitor arm, infusion pump etc.
• CE marked, meets EU clinical requirement
• Optional monitoring functions, CO2 and anesthetic gas
• Flowmeter provides minimum 25% concentration of oxygen in O2 /N2O mixture
• Breathing system easy to remove and clean, fully autoclavable, optional CO2 bypass
• Enhances usability with auxiliary oxygen, suction, auxiliary power source, monitor arm, infusion pump etc.
• CE marked, meets EU clinical requirement
Physical & Environment Specifications | |
Dimensions(W×H×D) | 704mm × 1403mm × 750mm |
Weight | 100kg (basic unit) |
Storage Humidity: | ≤93% (noncondensing) |
Operation Humidity | ≤80% (noncondensing) |
Electrical Specifications | |
Mains | 100~240V AC, 50/60Hz |
Battery | 24V DC, minimum 120 min |
Outlets | 3 on back, 1.5A individual |
Pneumatic Specifications | |
Gas Supply | Air, O2, N2O; 280kPa ~ 600kPa |
Flowmeters | O2 Range: 0~1L/min; 1~10L/min N2O Range: 0~1L/min; 1~10L/min Air Range: 0~1L/min; 1~10L/min Auxiliary O2 Range: 0 ~12 L/min |
Gas System | Flowmeter backlight Oxygen supply failure alarm N2O-cut-off system O2 flush: 25~75L/min |
ACGO | Optional auxiliary common gas outlet |
AGSS | Optional anesthetic gas scavenging system |
Breathing System Specifications | |
Operational Modes | Closed, Semi-closed, Semi-open |
CO2 Canister | 2 Loose fill (3L) or 2 prepacks, optional single canister (1.8 L) |
APL Range | Spontaneous breathing (SP) -70 cmH2O |
Material | Autoclavable (except O2 cell and mechanical pressure gauge) |
CO2 bypas | Optional |
Ventilator Specifications | |
Driven Mode | Pneumatically driven and electronically controlled |
Patient Types | Adult, Pediatric |
Ventilation Modes | IPPV, PCV, SIMV+PS, PS and Manual |
Setting Modes | Touch key & navigator wheel knob |
Tidal Volume | 20~1500ml |
Ventilation Frequency | 4~100bpm |
I:E Ratio | 4:1~1:8 |
Pressure (inspired) Range | 5~70cmH2O |
Pressure (support) Range | 3~50cmH2O |
PEEP | Off,3~30 cmH2O |
Tslope | 0~2s |
Inspiratory Plateau | Off, 5%~60%Ti |
Trigger Sensitivity | 1~15L/min |
Compensation | Compliance and leakage compensation, fresh gas compensation and altitude compensation |
Ventilator Monitoring | |
Display | 10.4” TFT color screen |
Pressure | Ppeak, Pplat,Pmean,PEEP |
Volumes | MV, Vt, Freq |
YOUR MAY ALSO LIKE ...