Operation Room Biphasic Defibrillator YS-8000D
Item No.: YS-8000D
Operation room Biphasic defibrillator YS-8000D
Product parameters | |
Brand: | YSENMED |
MOQ: | 1 |
Package: | Carton Package |
Ship From: | Guangzhou |
Lead Time: | 3-15 days |
Customization: | YES |
Description
Operation Room Biphasic Defibrillator YS-8000D
Physical characteristics:
Main unit: Portable
Dimensions:L320xW205xH410
Weight:9.5kg
Technical specifications
DEFIBRILLATOR
(1)Defibrillator type Manual, Synchronized, Asynchronized,
(2)Out put waveform Biphasic technology
(3)Energy accuracy ∠+1%
(4)Energy selection 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joule (nominal ata resistance of 50)
(5)Charging time Maximum 8 seconds to 360 Joules
(6)Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated)
Power requirements.
(a)AC Power supply 110V, 60 Hz /220V, 50 Hz
(b)Vehicle Voltage DC 12V
Internal Battery Backup
(1)Battery type Rechargeable lead-acid battery
(2)Charging time Time-Minimum of 4 hours for full charging
(3)Battery charging During AC Power Supply operation of the device.
(4)Charging /Low Battery Indication Red LED
(5)Battery Capacity 100% of the battery will provide 120 mins of monitoring;
and 30 discharges at 360 joules.
Display
-LED Dimensions 7’diagonal {155mm*88mm} which is easily read from a distance.
-Type High resolution true-color graphic LED
-Resolution 480X234
- Provide cardioversion facilities with waveform annotated on the screen
- Display 4 seconds of ECG at 25mm/sec, ECG selectable from leads I, II, III when used
with a 3-lead cable, and I, II, III aVL, aVR, aVF and V when used with a 5-lead cable.
- Display prompts, waveform settings, battery status, event summary and fault codes.
Energy selected is displayed by push button under the screen.
ECG
ECG lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1~V6, GND
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical
knife and defibrillation
Respiration
Measurement method: Thoracic impedance
Standard parameter & configuration
ECG/ RESP/DEFIBRILLATOR
-Provide audible and visual alarms for heart rate violations, VF and VT.
-Provide a strip printer which annotates waveforms, events, time code
-Have a 5-lead patient cable as an option to a 3-lead cable.
-Supplied with external re-usable paddles and packs of paper rolls for the printer.