Categories
Anesthesia System YSAV6301
Item No.: YSAV6301
Product parameters | |
Brand: | YSENMED |
MOQ: | 1 |
Package: | Wooden Package |
Ship From: | Guangzhou |
Lead Time: | 7 days |
Customization: | Customized packaging |
Description
Features:
1.Integrated breathing circuit with APL valve, excellent tightness.
2.Replacing drive bellow is NOT required when operating adult/pediatric anesthesia.
3.Applied with 1 high-precision vaporizers. (Selectatec).
4.10.1 inch screen.
5.Real-time detection for loops, Paw, BPM, VT and compliance.
6.Comprehensive monitoring capabilities include ventilation parameters monitoring, preset parameters, alarm indication and breathing waveform monitoring.
7.ACGO available to connect with T/Bain circuit for open operation (Optional).
Technique Specifications
Physical Specifications
Dimensions: 70*85*140cm
Weight: 65kg
Casters: Front wheels with lock
Screen: 10.1 inch LCD screen
Display graphic: Waveforms of P-T,F-T,V-T
Working specifications
Power: AC 110V-240V,50Hz/60Hz
Battery Power: ≥180 mins
Pipeline Supply
Gas configuration: O2,N2O,Air(Optional)
Pipeline input range: 280-600Kpa(40-85psi)
Ventilator Specifications
Applications
Patient range: Adult/Pediatric
Modes of Ventilation
VCV: Volume Control Ventilation
SIMV: Synchronized Intermittent Mandatory Ventilation
Manual
STAND-BY
A/C: Assist/Control
Ventilator Parameter
Working type: Electronic control, pneumatic driven
Tidal Volume range: 20-1500ml
Pressure range: 5-60cmH2O
Rispriation rate range: 1-100bpm(1-40bpm under SIMV)
I:E range: 4:1-1:8
Ptrigger range: -20-0cmH2O
Minute volume range: >18L/Min
SIGH range: 0-5/100
System Standard
Hypoxic guard system: N2O cut-off Valve, O2 concentration>25%
Safety valve:<12.5Kpa
O2 Flush: 25-75L/min
Flow meter: 4 tubes, cascade 0-15L/min O2, 0-15L/min N2O, 0-15L/min air (Optional)
Volume of CO2 absorber: 2L
Vaporizer: 1 Selectetac, maximum 2 mounts (Isoflurane/Enflurane/Sevoflurane/Halothane)
Monitoring: VT, MV, Pmax, Pmean, Lung compliance,Freq, FiO2(optional), ETCO2(optional)
Alarm Limits
Audio/Visual: No tidal volume, MV, Paw, Fio2(optional),Air failure, AC power failure, Battery low
Pre-setting functiuons
Language: CHJINESE, ENGLISH etc.
Self-test: Automatic
Optional features
1.ACGO: Auxiliary Common Gas Outlet
2.Yoke system(Pin-index): Support 11L cylinder O2,N2O
3.AGSS: Anesthetic Gas Scavenging Systems
1.Integrated breathing circuit with APL valve, excellent tightness.
2.Replacing drive bellow is NOT required when operating adult/pediatric anesthesia.
3.Applied with 1 high-precision vaporizers. (Selectatec).
4.10.1 inch screen.
5.Real-time detection for loops, Paw, BPM, VT and compliance.
6.Comprehensive monitoring capabilities include ventilation parameters monitoring, preset parameters, alarm indication and breathing waveform monitoring.
7.ACGO available to connect with T/Bain circuit for open operation (Optional).
Technique Specifications
Physical Specifications
Dimensions: 70*85*140cm
Weight: 65kg
Casters: Front wheels with lock
Screen: 10.1 inch LCD screen
Display graphic: Waveforms of P-T,F-T,V-T
Working specifications
Power: AC 110V-240V,50Hz/60Hz
Battery Power: ≥180 mins
Pipeline Supply
Gas configuration: O2,N2O,Air(Optional)
Pipeline input range: 280-600Kpa(40-85psi)
Ventilator Specifications
Applications
Patient range: Adult/Pediatric
Modes of Ventilation
VCV: Volume Control Ventilation
SIMV: Synchronized Intermittent Mandatory Ventilation
Manual
STAND-BY
A/C: Assist/Control
Ventilator Parameter
Working type: Electronic control, pneumatic driven
Tidal Volume range: 20-1500ml
Pressure range: 5-60cmH2O
Rispriation rate range: 1-100bpm(1-40bpm under SIMV)
I:E range: 4:1-1:8
Ptrigger range: -20-0cmH2O
Minute volume range: >18L/Min
SIGH range: 0-5/100
System Standard
Hypoxic guard system: N2O cut-off Valve, O2 concentration>25%
Safety valve:<12.5Kpa
O2 Flush: 25-75L/min
Flow meter: 4 tubes, cascade 0-15L/min O2, 0-15L/min N2O, 0-15L/min air (Optional)
Volume of CO2 absorber: 2L
Vaporizer: 1 Selectetac, maximum 2 mounts (Isoflurane/Enflurane/Sevoflurane/Halothane)
Monitoring: VT, MV, Pmax, Pmean, Lung compliance,Freq, FiO2(optional), ETCO2(optional)
Alarm Limits
Audio/Visual: No tidal volume, MV, Paw, Fio2(optional),Air failure, AC power failure, Battery low
Pre-setting functiuons
Language: CHJINESE, ENGLISH etc.
Self-test: Automatic
Optional features
1.ACGO: Auxiliary Common Gas Outlet
2.Yoke system(Pin-index): Support 11L cylinder O2,N2O
3.AGSS: Anesthetic Gas Scavenging Systems
YOUR MAY ALSO LIKE ...