Table-top Fully automatic chemistry analyzer YSTE180C
Item No.: YSTE180C
Desk-top Clinical Automatic Chemistry Analyzer YSTE180C High Performance
Product parameters | |
Brand: | YSENMED |
MOQ: | 1 |
Package: | Carton package |
Ship From: | Guangzhou |
Lead Time: | 7-10 days |
Customization: | yes |
Description
Desk-top Fully Automatic Chemistry Analyzer YSTE180C
► Throughput constant 180 T/h or 300T/h,best for middle or small size hospital
► Closed integrated photovoltaic systems, no mechanical parts,maintenance free
► Minimum reaction volume is 150ul,cost saving
► Discrete,random access,automatic
► Random choice of method, the real discrete automatic chemistry analyzer
► This automatic chemistry analyzers have gained a lot of national patents during the researching
Test Projects
► ALT、AST、TP、ALB、TBIL、DBIL、ALP、r-GT、CHE、TBA、5-NT
► UREA、CR、UA、TCO2
► CHOL、TG、HDL、LDL、ApoA、ApoB、LPa
► AMY、LIP
► GLU、GSP
► CK、CK-MB、a-HBDH、LDH、MB
► CRP、RF、ASO
► Throughput constant 180 T/h or 300T/h,best for middle or small size hospital
► Closed integrated photovoltaic systems, no mechanical parts,maintenance free
► Minimum reaction volume is 150ul,cost saving
► Discrete,random access,automatic
► Random choice of method, the real discrete automatic chemistry analyzer
► This automatic chemistry analyzers have gained a lot of national patents during the researching
Yuesen Med® YSTE0202 Automatic Chemistry Analyzer |
Specifications | ||
Analyze Unit | |||
Throughput | Constant 180T/h (non-ISE) | ||
Theory | Absorption spectrometry, transmission turbidimetry | ||
Methodology | End-point、Fixed-time、Kinetic、Ion selective electrode | ||
Test according set up, random access | |||
Reaction plate | Contain 81 reaction cuvettes | ||
Maximum reaction time | 15 minutes | ||
Minimum reaction volume | 150 ul | ||
Material of cuvettes | Special UV-transparent optical glass | ||
Cuvettes use | Automatically cuvettes washing | ||
Optical Unit | |||
Light Source | Halogen-tungsten lamp | ||
Photometer | Reversed optics | ||
Wavelength | 340nm-900nm wavelength option | ||
Absorption | 0-4 Abs | ||
Reagent Unit | |||
Reagent plate | 60 reagent positions,support for single and double reagent, reagent completely open | ||
Reagent storage temperature | 2~10℃ | ||
Reagent bottle | 15ml, 20ml, 30ml, 50ml or 70ml,dead volume is less than 1.0 ml | ||
Reagent volume | 20-500 ul, step by 1.0 ul | ||
Reagent/Sample Probe | Automatically checked;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. | ||
Sample Unit | |||
Sample plate | 60 sample positions | ||
Sample type | Human (animal) serum、plasma、urine etc. | ||
Samples cup | Support one-off micro cups | ||
Sample volume | 2-100 ul, step by 0.1 ul | ||
Sample/reagent probe | Automatically checked;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. | ||
Temperature control Unit | |||
Heating method | Direct thermal solid thermostat closed | ||
Temperature equilibrium time | <3 minutes | ||
Reaction temperature | 37±0.1℃ | ||
Temperature fluctuation | ±0.1℃ | ||
Operation Unit | |||
Software | WindowsXP、2000 | ||
Database | SQL Server | ||
Data Storage | Automatic store & copy; No time and volume limit; Lifetime preservation | ||
Print format | Can be set up, offer several standard format | ||
Calibration mode | Linear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard | ||
Quality control methods: | Real time, within day & between day | ||
Quality control diagram | L-J、cumulative、twin plot | ||
Status display | Real time monitoring of reagent residual volume。Running status of reagent tray, samples tray | ||
Adjustment | Dynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages | ||
Setting | Operation permission setting, Item setting, cross pollution setting, cuvette blank setting | ||
Others | |||
Water consumption: <6L/h | Power Supply: AC 220V±22V 50Hz±1Hz | ||
Frequency: Maximum 600VA | Dimension: 782mm×581mm×545mm | ||
Net Weight: 60kg | Accessory: Software |
Test Projects
► ALT、AST、TP、ALB、TBIL、DBIL、ALP、r-GT、CHE、TBA、5-NT
► UREA、CR、UA、TCO2
► CHOL、TG、HDL、LDL、ApoA、ApoB、LPa
► AMY、LIP
► GLU、GSP
► CK、CK-MB、a-HBDH、LDH、MB
► CRP、RF、ASO