We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.

Professional Medical Equipment Supplier - Yuesen Med Professional Medical Equipment Supplier - Yuesen Med

Categories

X-ray dosimeter YSX1628

Item No.: YSX1628
High Performance YSX1628 X/Y ray Radiation Dosimeter Good Price
Product parameters
Brand: YSENMED
MOQ: 1
Package: Carton Package
Ship From: Guangzhou
Lead Time: 3-7 days
Customization: Yes
Get Price
Description
High Performance YSX1628 X/Y ray Radiation Dosimeter

The portable radioactive contamination dosimeter is a wearable device,which id produced with the functionally powerful MCU technology.

It is mainly for testing x-ray and y-ray, and directly reading the dose and dose rate.

In the scope of its measurement, the alarming threshold can be fixed or pre-set.When the threshold is overrun or block dose happens, the meter will send out light and sound alarm signals. As a wearable device, it features small size and low power.
It is widely used in such fields as non-destructive flaw detection, nuclear power station,nuclear submarine, isotope application, and cobalt therapy in hospital.

Features:
1. High sensitivity, and response to environmental background.
2. Measuring both dose and dose rate, and providing various alarming signals.
3. Low power, small size, and easy use.

Technical parameter:
1. Detector:GM counting tube, measuring X-ray and γ-ray;
2. Display screen: 4 numbers LCD;
3. Measuring range:
    Accumulated dose equivalent: Hp(10)0.0usv~99.99msv;
    Dose equivalent rate: Hp (10)0.1usv/h~99.99msv/h;
4. Response time: 3.6S-36S;
5. Measuring rate response: <±20%(1usv/h~99.99msv/h)
6. Energy response: <±30%(50KeV~1.3MeV)
7. Relative inherent error: <±20%(137Cs).
8. Alarm function and alarm valve value: Measuring rate and accumulated dose can preset alarm valve value in the measuring range. The fixed alarm valve value as follows:
    1).Accumulated dose: Per increase 0.1usv, a short noise and light each time: ≥50 usv, sound-light alarm5s,"ALARM"display.
    2.) Measuring rate: ≥25usv/h,sound-light alarm is about 6s,"ALARM" display.
    3. )Clogging alarm: when counting tube clogged, alarm continuously, "ALARM" display, alarm sound intensity is about 80 decibels at the 30 cm.
9. The battery under voltage indicates: when Battery voltage <2.7 +/- 0.05 Vs, the instrument displays under voltage symbol "LOBAT". It still can work for more than 24 hours in the lower radiation place after under voltage symbol appears.
10. Battery and consumption: AAA type 1.5 V alkaline battery(7#battery), consumption<2mw, continuous service: 720 hours.
11. Temperature characteristic: < ±10%- 10degree -- +50degree.
12. Temperature features: <±10% 95%RH(+35%);
13. Size: 55(width)×92(length)×18(thickness).
14. Weight: <75g,including battery <98g.


High Performance YSX1628 X/Y ray Radiation Dosimeter

High Performance YSX1628 X/Y ray Radiation Dosimeter

Yuesen Med equipment purchase process
Get Price
Write down your demand below and we will contact you within 24h!

YOUR MAY ALSO LIKE ...