Categories
YSCT-32D X-ray Computed Tomography Equipment
Item No.: YSCT-32D
The X-ray source assembly rotates 360°, and the maximum number of scan layers that can be obtained in a single axial scan is 32.
Scan mode: positioning scan, tomographic scan, spiral scan, enhanced scan, perfusion scan.
Scan mode: positioning scan, tomographic scan, spiral scan, enhanced scan, perfusion scan.
Product parameters | |
Brand: | YSENMED |
MOQ: | 1 |
Package: | Wooden Package |
Ship From: | Guangzhou |
Lead Time: | 3-15 days |
Customization: | Customized package |
Description
Parameters
The X-ray source assembly rotates 360°, and the maximum number of scan layers that can be obtained in a single axial scan is 32.
Maximum scanning range: 1200mm
Pitch coefficient: 0.25, 0.5, 0.75, 1, 1.25, 1.5, 1.75
Scan mode: positioning scan, tomographic scan, spiral scan, enhanced scan, perfusion scan
Software function
Patient file management
Patient registration
Scan function
reconstruction
2D image browsing and processing
3D image browsing and processing
Film printing
Data management function
Part name | Model | Specifications |
Scanning frame | SM100 | Scanning frame aperture: 700mm±10mm Scanning frame rotation speed: 0.75s, 1.0s, 1.5s, 2.0s Scanning field of view: 430mm Type of Slip ring: contact slip ring |
High voltage generator | CT70PN32X5610 | Tube voltage setting: 70~140kV Tube current range: 10~300mA Nominal output power: 32kW |
Collimator | CMT-003 | Half value layer:≥4.6mmAl Equivalent aluminum equivalent thickness:2.3mmAl |
X-ray tube sleeve | B-240H | Nominal tube voltage: 140kV Nominal anode input power: 29kW/48kW Maximum continuous heat dissipation of anode: 3.5kW Focus size: 0.7mm ×0.8mm 1.2mm ×1.4mm Anode rotation speed: 60Hz/180Hz Diameter of anode target surface (mm): 140mm Target angle: 7° Anode type: rotating anode Bearing type: mechanical bearing Quantity (pcs): 1 Fly focus (x to z offset): none The longest spiral scanning time: 100s Anode heat capacity:3.5MHU |
X-ray tube | GS-30722 | |
Detector | DET-003 | Scintillation crystal material: GOS crystal Pixel matrix: 704×16 Number of detectors: 11 Coverage (projected to the center of rotation): 430mm Pixel size (projected to the center of rotation) 1.25mm × 1.25mm Scanning angle: 0°/90° Scanning field of view: 430mm Axial scanning layer thickness: 1.25 mm ± 0.625 mm, 2.50 mm ± 1.0 mm, 5.00 mm ± 1.0 mm, 10.0 mm ± 1.0 mm; Spiral scanning layer thickness: 1.25 mm ± 0.625 mm, 2.50 mm ± 1.0 mm, 3.75 mm ± 1.0 mm, 5.00 mm ± 1.0 mm, 7.50 mm ± 1.0 mm, 10.0 mm ± 1.0 mm; Collimation combination: 16×1.25, 4×1.25; |
Diagnostic bed | ZC300 | Z-axis positioning accuracy (mm): ≤±1mm Speed: 0~150mm/s Vertical lifting range: ≥440mm Maximum load: 205kg |
Laser | M63AXSAXX-XX | Category: 2 types Positioning accuracy: ±1mm Wavelength: 600~700nm Maximum output power: <1mW |
Console CZ100 |
KH100 | Control box: Exposure control Bed motion control Intercom function |
/ | Computer The minimum configuration requirements are as follows CPU performance: the main frequency is not less than 2 GHz, the number of cores is not less than 2 cores Memory size: no less than 8GB Image storage capacity: no less than 850GB |
|
/ | Monitor The minimum configuration requirements are as follows Screen resolution: 1920×1200 SXGA Number of displays size: 1*24 inches Type: LCD, color Contrast ratio: 1000:1 Preview |
|
Computer image processing software | ScintVue | Release version: 1.0 |
The X-ray source assembly rotates 360°, and the maximum number of scan layers that can be obtained in a single axial scan is 32.
Maximum scanning range: 1200mm
Pitch coefficient: 0.25, 0.5, 0.75, 1, 1.25, 1.5, 1.75
Scan mode: positioning scan, tomographic scan, spiral scan, enhanced scan, perfusion scan
Software function
Patient file management
Patient registration
Scan function
reconstruction
2D image browsing and processing
3D image browsing and processing
Film printing
Data management function
YOUR MAY ALSO LIKE ...