Categories
YSX-DM98B Digital Mammography X-ray System
Item No.: YSX-DM98B
Digital Mammography X-ray System YSX-DM98B
Product parameters | |
Brand: | YSENMED |
MOQ: | 1 |
Package: | Wooden Package |
Ship From: | Guangzhou |
Lead Time: | 1-3 days |
Customization: | Yes |
Description
Technical Specification
No. | Item | Specification |
1 | X-ray Generator | |
1.1 | Generator Type | High Frequency Inverter 80kHz |
1.2 | Input Power | Single Phase 220VAC, 50/60Hz |
1.3 | Radiographic Ratings | Large Focal Point 20-35kV/10-510mAs |
Small Focal Point 20-35kV/10-100mAs | ||
1.4 | Power Rating | 6.2kW |
2 | X-ray Tube | |
2.1 | Model | China Hangzhou LR01 |
2.2 | Focal Spot Size | Dual Focus 0.2 / 0.4mm |
2.3 | Target Material | Molybdenum (Mo) |
2.4 | Port Material | Beryllium (Be) |
2.5 | High-speed Anode Drive | 2800rpm |
2.6 | Target Angle | 12° |
2.7 | Anode Heat Storage | 80kJ(110kHU) |
2.8 | Anode Cooling | Air Cooling |
2.9 | Filtration | Mo(0.03mm) |
3 | Radiographic Stand | |
3.1 | U-arm Vertical Movement | 590mm |
3.2 | Rotations Deg | +90°~-90° |
3.3 | SID | 650mm |
3.4 | Compressor | The compressor is automatically released after the exposure is completed |
3.5 | Compressor Max. Pressure | 200N |
3.6 | Compressor Max. Travel | 156mm |
4 | Detector | |
4.1 | Detector Material | Amorphous Silicon |
4.2 | Effective Coverage Of Detector |
24cm×30cm |
4.3 | Pixel Matrix | 2816×3528 |
4.4 | Limit Of Spatial Resolution | 6.0Lp/mm |
4.5 | DQE Value | @4 Lp/mm:≥35% |
4.6 | Dynamic Range | 14bit Digital Output |
4.7 | Pixel Size | 85μm |
4.8 | Output | Ethernet |
4.9 | Working Condition | 10℃-40℃ |
4.10 | Storage Environment | -10℃-50℃ |
5 | Image Acquisition Workstation Hardware |
|
5.1 | CPU | Intel Core Duo 3.0GHz |
5.2 | Hardware | ≥1T high Speed Hardware |
5.3 | Memory | ≥8G |
5.4 | Display Card | ≥2G |
5.5 | High Brightness High-contrast LCD |
1920*1080Pixel Resolution |
5.6 | Network interface Worklist | DICOM3.0 Transmission |
100/1000 Gigabit Ethernet | ||
5.7 | Software | Imaging Software Package DMOC V1.0 |
Standard configuration
No. | Configuration | Quantity |
1 | Mammography machine host | 1 |
X-ray tube for breast | 1 | |
High frequency X-ray generator | 1 | |
Mammography column | 1 | |
Electric lifting and rotating U-shaped arm | 1 | |
Console | 1 | |
2 | Foot switch | 1 |
3 | Exposure hand brake and connection | 1 |
4 | Supporting cables include: | - |
Dedicated three-wire power cord | 1 | |
Dedicated ground wire | 1 | |
Spare fuse | 2 | |
5 | Flat panel detector | 1 |
6 | Control system of special high-pressure generator for breast | 1 |
7 | Breast image acquisition system | 1 |
DM image acquisition software package | 1 | |
DMOC image processing module |
YOUR MAY ALSO LIKE ...