High Performance 3.5KW 5KW Mega-pixel Digital C-arm X-ray Machine YSX-C35D
YSX-C35D Specifications
1.Combined X-ray tube & generator
2.9inch Toshiba Image Intensifier
3.get the clearest images with minimum dose

YSX-C35D Technical parameters and configuration:
Main components Technique parameter
IMD X-ray tube Model:YSX-C35D Model:YSX-C50D
Power:3.5kW Power:5.0kW
Double focus fixed anode focus:1.5mm / 0.6mm Double focus rotational anode focus: 0.3mm / 0.6mm
Anode Heat Capacity:40kHu X-ray tube sleeve heat capacity:667kHu Anode Heat Capacity:200kHu X-ray tube sleeve heat capacity:800kHu
High Voltage X-ray Generator Working frequency:40kHz
Image intensifier Toshiba 9"(including 3 fields of view 4.5"/ 6"/9")
Tube voltage Fluoroscopy Radiograph:40kV-110kV Fluoroscopy Radiograph:40kV-120kV
Tube current Fluoroscopy: 0.5-4mA  Enhanced  Automatic Fluoroscopy: 1mA-8mA    Pulse  Fluoroscopy :2pps;8mA
mAs 1mA.s-250mA.S
Fluoroscopy  mode Manual  Fluoroscopy; Semi-Automatic Fluoroscopy;Automatic Fluoroscopy; Enhanced  Automatic Fluoroscopy; Pulse  Fluoroscopy
Intelligent exposure control No matter the object is in the center or on the fringing field of the image intensifier, the images are the same. The exposure dose is reduced.
Iris beam limiting device when not exposure, keep in the state of Iris Beam limiting preview ,when exposure,keep blanking cycle track
General radiography 40kV-120kV; 1.0mA.s-250mA.s step length 1 kV; 1.0mA.s
Digital radiography (digital spot film) 40kV-120kV; Max 16mA Common screen film radiography is eliminated. Digital radiography can get better images
C-arm machinery index Distance between focus and window≧900mm, arc depth≧650mm, horizontal moving range: 200mm vertical moving range: 400mm
Tilt angle: ±12.5°  rotation: ±180°corner: 125°(-35°-- +90°)
Laser Orientation Laser positioning function can help to position precisely and reduce exposure times in the operation, reduce unnecessary radiation.
Radiography mode
Image intensifier & Real-time digital image(1.3 million pixel) processing system
(CCD)Digital video camera million pixels high-definition, high-speed CCD camera, a 1024 × 1024 matrix, 30 frames per second image acquisition, through real-time adjustment of window width, window level, noise reduction, sharpening and Gain adjustment to ensure high-quality and high-resolution images.
Image resolution  index Grey level:10  Resolution:22 lp/cm
Camera virtual  rotation design No X-ray needed, also called digital image rotation,display the right angle when exposure, superior to camera mechanical rotation
Image processing  system 1.Real time edge  enhancement(sharpening) Image sharpening is also called edge enhancement, that is, to make  blurry edge of the image clearer
2.Real time adjustment of the window width and window level Obtain images by real-time adjustment of window width,window level, displaying images with different brightness.
3.Real time(static)multiform noise reduction Noise reduction, and improve image clarity
4.Real tim GAIN adjustment Can amplify image signal, reduce x-ray dose, suitable for patient with super large size.
5.Real tim dynamic brightness compensation and R calibration functions Through dynamic logarithmic transformation, linear reduction the system signals and r calibration technology, dark parts of the image can be enhanced and clear rich-layer images can be obtained
6.Image conversing ,up-down and right-left rotating, and frame freezing
7.Patient information management, Clinic report and print
8.The Image can be storage as JPG and DICOM 3.0 format, can be linked to hard-disk, USB and DVD and printer, meet the need of sharing the network information, communication and storage in hospital
Display Display2 17"TFT-LCD display
Printer Printer Laser / jet Printer
Standard configuration 1.Combined tube(5.0kW)IMD 1 set;
2.Image intensifier (9 inch 3 fields of view) Toshiba 1 set
3.C-arm stander (with full C-arm balance system) 1 set;
4.Exported grid 1 set
5.Laser positioning 1 set;
6.1.3million pixel 1024×1280×10bit camera 1 set;
7.Electric adjustable beam limiting device 1 set
8.17 inch LCD high resolution screen 2 sets
9.Real-time digital imageprocession system (station) 1 set;
10.Printer 1 set
 
Yuesen Med equipment purchase process
Obtenha o preço
Escreva abaixo o seu pedido e entraremos em contacto dentro de 24h!

YOUR MAY ALSO LIKE ...
Sistema de raio X digital de braço C com detector de painel plano de 15kW YSX-C715
Sistema de raio X digital de braço C com detector de painel plano de 15kW YSX-C715
Digital C-arm X-ray System with Flat Panel Detector YSX-C605
Digital C-arm X-ray System with Flat Panel Detector YSX-C605
Sistema de raio-X digital de braço C de 5,0 kW
Sistema de raio-X digital de braço C de 5,0 kW
YSX-C35B móvel de alta frequência do sistema de imagem do C-braço
YSX-C35B móvel de alta frequência do sistema de imagem do C-braço