Система Digital Pixels C-arm
Предмет №: YSX-C50D
Новейшая система Digital Pixels C-arm для продажи по хорошей цене.
Параметры продукта | |
Марка: | YSENMED |
MOQ: | 1 |
Упаковка: | Картонная упаковка |
Доставить из: | Guangzhou |
Время выполнения заказа: | 1-3 дня |
Настройка: | Yes |
ОПИСАНИЕ
Digital Pixels C-arm System
Technical Specifications & Configuration
Main components | Technique parameter | |||
IMD X-ray tube | YSX-C35D | YSX-C50D | ||
Power:3.5kW | Power:5.0kW | |||
Double focus fixed anode focus:1.5mm / 0.6mm | Double focus rotational anode focus: 0.3mm / 0.6mm | |||
Anode Heat Capacity:40kHu X-ray tube sleeve heat capacity:667kHu | Anode Heat Capacity:200kHu X-ray tube sleeve heat capacity:800kHu | |||
High Voltage X-ray Generator | Working frequency:40kHz | |||
Image intensifier | Toshiba 9"(including 3 fields of view 4.5"/ 6"/9") | |||
Tube voltage | Fluoroscopy Radiograph:40kV-110kV | Fluoroscopy Radiograph:40kV-120kV | ||
Tube current | Fluoroscopy: 0.5-4mA Enhanced Automatic Fluoroscopy: 1mA-8mA Pulse Fluoroscopy :2pps;8mA | |||
mAs | 1mA.s-250mA.S | |||
Fluoroscopy mode | Manual Fluoroscopy; Semi-Automatic Fluoroscopy;Automatic Fluoroscopy; Enhanced Automatic Fluoroscopy; Pulse Fluoroscopy | |||
Intelligent exposure control | No matter the object is in the center or on the fringing field of the image intensifier, the images are the same. The exposure dose is reduced. | |||
Iris beam limiting device | when not exposure, keep in the state of Iris Beam limiting preview ,when exposure,keep blanking cycle track | |||
General radiography | 40kV-120kV;1.0mA.s-250mA.s | step length 1 kV;1.0mA.s | ||
Digital radiography (digital spot film) | 40kV-120kV;Max 16mA | Common screen film radiography is eliminated. Digital radiography can get better images | ||
C-arm machinery index | C-arm stander(with perfect C arm balance system) of ultra-quiet motor-driven up and down, easy and handy to operate. The machine can maintain balance with up and down of the C arm. | |||
Distance between focus and window≧900mm, arc depth≧650mm, horizontal moving range :200mm vertical moving range:400mm | ||||
Tilt angle :±12.5° rotation :±180°corner:125°(-35°-- +90°) | ||||
Laser Orientation | Laser positioning function can help to position precisely and reduce exposure times in the operation, reduce unnecessary radiation. | |||
Radiography mode | ||||
Image intensifier & Real-time digital image(1.3 million pixel) processing system | ||||
(CCD)Digital video camera | million pixels high-definition, high-speed CCD camera, a 1024 × 1024 matrix, 30 frames per second image acquisition, through real-time adjustment of window width, window level, noise reduction, sharpening and Gain adjustment to ensure high-quality and high-resolution images. | |||
Image resolution index | Grey level:10 Resolution:22 lp/cm | |||
Camera virtual rotation design | No X-ray needed, also called digital image rotation,display the right angle when exposure, superior to camera mechanical rotation | |||
Image processing system | 1.Real time edge enhancement(sharpening) | Image sharpening is also called edge enhancement, that is, to make blurry edge of the image clearer | ||
2.Real time adjustment of the window width and window level | Obtain images by real-time adjustment of window width,window level, displaying images with different brightness. | |||
3.Real time(static)multiform noise reduction | Noise reduction, and improve image clarity | |||
4.Real tim GAIN adjustment | Can amplify image signal, reduce x-ray dose, suitable for patient with super large size. | |||
5.Real tim dynamic brightness compensation and R calibration functions | Through dynamic logarithmic transformation,linear reduction the system signals and r calibration technology, dark parts of the image can be enhanced and clear rich-layer images can be obtained | |||
6.Image conversing ,up-down and right-left rotating,and frame freezing | ||||
7.Patient information management ,Clinic report and print | ||||
8.The Image can be storage as JPG and DICOM 3.0 format, can be linked to hard-disk ,USB and DVD and printer,meet the need of sharing the network information ,communication and storage in hospital | ||||
Display | Display2 17"TFT-LCD display | |||
Printer | Printer Laser / jet Printer | |||
Standard configuration | 1.Combined tube(5.0kW)IMD | 1 set; | ||
2.Image intensifier (9 inch 3 fields of view) Toshiba | 1 set | |||
3.C-arm stander (with full C-arm balance system) | 1 set; | |||
4.Exported grid | 1 set | |||
5.Laser positioning | 1 set; | |||
6.1.3 million pixel 1024×1280×10bit camera | 1 set; | |||
7.Electric adjustable beam limiting device | 1 set | |||
8.17 inch LCD high resolution screen | 2 sets | |||
9.Real-time digital imageprocession system (station) | 1 set; | |||
10.Printer | 1 set |