Продукция
5kW мобильный высокочастотный диагностический рентгеновский аппарат YSX100GM
Предмет №: YSX100GM
5kW мобильный высокочастотный диагностический рентгеновский аппарат YSX100GM
Параметры продукта | |
Марка: | YSENMED |
MOQ: | 1 |
Упаковка: | Деревянный пакет |
Доставить из: | Guangzhou |
Время выполнения заказа: | 1-3 дня |
Настройка: | Yes |
ОПИСАНИЕ
5kW Mobile High Frequency Diagnostic X-Ray Machine YSX100GM
Combined X-Ray Tube Assembly
1,Adopt high frequency high voltage generator and combined X-ray tube assembly;
2,kV closed-loop control, stable output, good repeatability, quick response and high accuracy;
3,mAs digital closed-loop control technology and 32-bit microprocessor real-time control, which ensure the accuracy and repeatability of dosage;
Inverter
1,Equipped with the functions of high voltage and over & under voltage protection, tube current over-current protection, output overload protection and fault prompt;
2,Perfect heat capacity protection function to protect X-ray tube target surface;
Corrugated Pipe
Full consideration of hospital disinfection and cleaning, adopt high quality corrugated pipe, prolonging the service life of the equipment
Switch
Using high quality switch, safe and reliable, stable quality
Technique Specification
Model | YSX70GM-B | YSX100GM | |
Power | |||
Input Voltage | 220V±10% | ||
Input Power | 5.5kW | 7.5kW | |
Mains Frequency | 50Hz±1Hz | ||
Source Resistance | ≤0.5Ω | ||
Main Technical Parameters | |||
Power Modules | 30kHz | ||
Filament Frequency | 20kHz | ||
Focus | 1.5mm | ||
Max. Generator Output | 3.5kW; | 5kW | |
Max. X-Ray Tube Voltage | 110KV | 120KV | |
kV Range | 40~120kV | ||
mAs Range | 1~125mAs | 1~200mAs | |
Main Parameters Of Mechanical Parts | |||
X Ray Tube Vertical Motion Range | ≥500~1750mm | ||
X Ray Source Components Around The Cross Arm Vertical Rotation:≥±90° | |||
Exposure Size | ≥350mm*350mm(SID=65cm) | ||
Machine Main Function | |||
Fault Detection Error Prompt Functions | |||
ARP Human Anatomy Program Function | |||
Parameter Calibration Function |
Combined X-Ray Tube Assembly
1,Adopt high frequency high voltage generator and combined X-ray tube assembly;
2,kV closed-loop control, stable output, good repeatability, quick response and high accuracy;
3,mAs digital closed-loop control technology and 32-bit microprocessor real-time control, which ensure the accuracy and repeatability of dosage;
Inverter
1,Equipped with the functions of high voltage and over & under voltage protection, tube current over-current protection, output overload protection and fault prompt;
2,Perfect heat capacity protection function to protect X-ray tube target surface;
Corrugated Pipe
Full consideration of hospital disinfection and cleaning, adopt high quality corrugated pipe, prolonging the service life of the equipment
Switch
Using high quality switch, safe and reliable, stable quality
YOUR MAY ALSO LIKE ...
YSENMED YSX-mDR32 32кВт 400мА Медицинский цифровой мобильный рентгеновский аппарат
YSX200GM-B 20KW/200mA HF Мобильный медицинский диагностический рентгеновский аппарат