We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.

Professional Medical Equipment Supplier - Yuesen Med Professional Medical Equipment Supplier - Yuesen Med

Hot Products

X Ray Machine  To  Zimbabwe

x ray machine, 50KW x ray machine

Microscope To Malawi

Achromatic objectives: 4X、10X、40X(S), 100X(S、Oil) Wide field eyepiece: WF10X(WF16X for option) Eyepiece head: Sliding binocular head inclined at 45° Stage: Double layer mechanical stage size 140X140mm, moving range 75X45mm Focusing: Coaxial coarse and

Color Doppler Trolley System To Somalia

Color Doppler Trolley System To Somalia

Automated Hematology Analyzer To Peru

High quality Automated Hematology Analyzer (3-part differential) with cheap price

GE Mobile X-ray machine fault

Views : 887
Author : Monica Liang
Update time : 2015-12-21 08:00:00

The machine over-current protection contactor triped and system was automatic power off when open the machine and pressed positioning lamp or exposure preparation in use.

Failure analysis and maintenance:

AMX-4+ system is consist of power box, charging control, CPU board, high voltage generator, motor control and remote control receiving. Every model is controled and detected by CPU. Then check attached machine circuit diagram and consider that positioning lamp(AC 24V, 150W) and exposure preparation(Rotating anode start ) are provided power by T1 transformer, it is controled by 46-232786G2.

The next step you could take down the board and measure, you would find that F93, which had insurance tube, is burned off and effective tube was breakdown. After replacing the same model tube, connect power and open the machine, fault remains. Then you would doubt CPU control singal abnormal and increase the load spurious. It leads to excessive current and power tube punctured. The following you could use digital multimeter to measure and 60Hz control singal is normal.

Replace the tube again and then connect power, the two test points are 5V and 6V. This two points are not balance. After power off, take down promote tube Q61, there is leakage phenomenon. After replacing the same model tube, connect power and measure two points are 6.0V. After opening the machine and self-inspection, fault is solved and x-ray machine can work normally.

Related News
Read More >>
Demostration video of YSENMED YSX-mDR32B 32kW Mobile Digital X-ray System. Demostration video of YSENMED YSX-mDR32B 32kW Mobile Digital X-ray System.
Nov .25.2024
Here we share the demostration video of YSENMED YSX-mDR32B 32kW Mobile Digital X-ray System.
The Future of Genetic Research: What You Need to Know About Auto Agarose Gel Electrophoresis The Future of Genetic Research: What You Need to Know About Auto Agarose Gel Electrophoresis
Nov .25.2024
Auto Agarose Gel Electrophoresis (AAGE) is one of the standout techniques making waves in laboratories. Let's dive deep into this fascinating topic.
Ecuadoran vet pleased with YSENMED YSDR-VET320 veterinary digital x-ray system Ecuadoran vet pleased with YSENMED YSDR-VET320 veterinary digital x-ray system
Nov .24.2024
YSENMED YSDR-VET320 32kW veterinary DR system has been installed in a vet clinic in Ecuador, and the doctor is pleased with its easy operation and sharp images.
Customer from Togo shares his good experience working with YSENMED Customer from Togo shares his good experience working with YSENMED
Nov .23.2024
Customer from Togo has purchased some medical equipment including color doppler ultrasound system YSB-S7, video endoscope system YSVME-200, oxgen concentrator, etc, with which he feels satisfied and considers re-purchase soon.