The several faults of Ultrasound probe

Views : 844
Author : Monica Liang
Update time : 2015-12-21 08:00:00

Ultrasound diagnosis equipment uses ultrasonic to extract all kinds of information of human tissue, such as organization interface information, blood flow information, so ultrasound probe, which can transfer information. Ultrasound probe is the key part of ultrasound diagnosis and its value has accounted for a quarter to a third of one ultrasound instrument total value, like B ultrasound probe is the same. In addition, doctors use it to check patients and it is easy to have faults. Therefore, it is necessary for reasonable using and maintenance.

In general, there are several faults of ultrasound probe as follows: Appearance cracking, internal sparkling, sensitivity decreasing, cable cracking and electrode lead break.

 First, Appearance cracking, internal sparkling, reduced sensitivity.

(1)Although ultrasound probe manufacturers are different, the basic structure is the same in general. Put the transducer in probe cavity of plastic wrap.

 As we know, when we examinate, checking parts have to been embrocated enough lotus root mixture, but this lotus root mixture is the biggest threat of plastic wrap. In most conditions, probe surface lotus root mixture is not clear and cause appearance cracking after finishing operation. After a long time, lotus root mixture has corrosion for the plastic and rubber band and damage probe. Therefore we must clean the surface lotus root mixture after finishing work and you had better use clean and wet soft cloth to wipe it; The other reason of appearance cracking is that probe is often influenced by the sun and large temperature difference. Because the sun will make plastic materials early ageing and deformation. So, ultrasound equipment should be placed in constant greenhouse and avoid light ray. For example probe frequency instability, you can consider probe moisture, then there is no effect after using no water copper sulfate moisture absorption; The following you use special tool to open probe shell and take down the circuit board and find that there is more circuit board oil and use 99.5% pure alcohol to soak ten minutes; Then use fuzz wipe oil and dirty; The next step, you can use fan to blow dry and put it back and open the machine, probe fault is removed.

(2) Internal sparkling. In general, probe production process defect causes sensitivity decrasing. It will happened after a period of time, especially bad penetration ability after adjusting host parameters.

Second, Circle image causes bad local

In general, chip problem cause this fault. For example, there is a white bright field from up to down and there is no imge information in this field. After checking, the probe internal chip damage causes this.

Third, Cable craze or electrode lead break

Due to probe move back and forth in use process, it will pull cable automatically, especially in turning probe process, it will make probe and the cable wind. Therefore, bad operation habit or cable placed bad cause this fault. For this fault, you can open probe shell and rearrange all lines and weld well, then use super glue sticky shell well.

 
Related News
Read More >>
Choosing the Right ELISA Microplate Reader for Your Lab: What You Need to Know Choosing the Right ELISA Microplate Reader for Your Lab: What You Need to Know
Sep .30.2024
In this article, we'll dive deep into everything you need to know about selecting the perfect ELISA microplate reader for your lab.
Lab Results on the Go: How Handheld Urine Analyzers are Changing Healthcare Lab Results on the Go: How Handheld Urine Analyzers are Changing Healthcare
Sep .29.2024
Let's dive into how handheld urine analyzers are changing the game in healthcare!
Portable Dry Biochemical Analyzers: Small Device, Big Impact in Medical Labs Portable Dry Biochemical Analyzers: Small Device, Big Impact in Medical Labs
Sep .27.2024
Let's dive into the fascinating world of portable dry biochemical analyzers and explore their role in modern medicine.
Australian vet content with YSENMED veterinary DR system and considers re-purchase Australian vet content with YSENMED veterinary DR system and considers re-purchase
Sep .27.2024
YSENMED YSDR-VET320 32kW veterinary digital x-ray system has passed the test and will come into service in a vet clinic in Australia. The vet is satisfied with the image quality and planning to purchase another unit for his other vet clinic.